What are the common faults in the ultrasonic cleaning machine before and after electrolysis deburring the workpiece:
1. Open the power switch of the ultrasonic cleaner and the indicator light does not light. The power switch and fuse should be checked due to damage to the power switch or blown fuse.
2. After turning on the power switch of the ultrasonic cleaner, the indicator light is on, but there is no ultrasonic output. It may be due to the loose plug of the transducer and the ultrasonic power board, or the fuse is blown, or the ultrasonic power attacker is faulty, or the transducer is faulty, it should be checked whether the above components are normal.
3. After turning on the power switch, the ultrasonic cleaner has ultrasonic output, but the cleaning effect is not satisfactory. It may be due to the improper liquid level of the cleaning liquid in the cleaning tank of the ultrasonic cleaning machine, or the ultrasonic frequency is not adjusted well, or the cleaning liquid is improperly selected. First, check whether the ultrasonic cleaning machine liquid level is reasonable, and then check the ultrasonic cleaning machine ultrasonic frequency and cleaning fluid.
How to maintain the ultrasonic cleaning machine before and after electrolysis deburring the workpiece:
1. Pay attention to the ultrasonic cleaning machine equipment clean, turn off the power when not in use.
2. Prevent collision or violent vibration of the ultrasonic cleaner equipment.
3. It should be prevented from storing the equipment in a humid environment.